Generac Generator LCD Screen Blank [6 Easy Fixes]

When you rely on your Generac Generator for power, encountering a blank LCD screen can be quite disconcerting. 

This key interface provides valuable information about the generator’s status, various settings, and potential issues. If it goes blank, you could be left guessing about the generator’s functionality. 

In this article, I’ll walk you through the reasons why your Generac generator LCD screen might be blank and how you can fix it.

Let’s dive in.

Generac Generator LCD Screen Blank

1 . Power Supply Issues

Power supply issues are not uncommon for Generac generators. 

They typically occur when there’s an interruption in the flow of electricity to the generator due to component failure, a blown fuse, or an unstable power source. 

This interruption can cause the LCD screen to go blank, preventing users from tracking or configuring the generator’s performance.

Key points to remember: Interruptions in electricity flow can cause power supply issues. These can be due to component failure, a blown fuse, or an unstable power source.

Solution

Resolving power supply issues with Generac generators often requires professional assistance. However, there are a few troubleshooting steps you can take at home.

 First, ensure the generator is connected to a reliable power source. Second, inspect the generator for any visible damage or loose connections.

 If the problem persists, contact a professional technician to avoid further damage or safety risks.

Key points to remember: Connect the generator to a reliable power source, inspect for visible damage or loose connections, and reach out to a professional technician if the issues persist.

2 . Faulty Control Board

A faulty control board is another common reason for a blank LCD screen on Generac generators. 

The control board is the brain center of the generator, managing all functions and operations. 

If it malfunctions due to component failure, wear and tear, or improper maintenance, this can result in an unresponsive or blank LCD screen.

Key points to remember: The control board manages all functions of the generator. Malfunctions can be due to component failure, wear and tear, or improper maintenance.

Solution

To fix a faulty control board, it is highly recommended to seek professional assistance as the process involves technical expertise. 

A certified Generac technician can run a full diagnostic check, identify the exact issue, and replace the control board if necessary. 

For preventive measures, regular maintenance of the generator, including the control board, can help avoid such issues.

Key points to remember: Seek professional assistance to fix a faulty control board. Regular maintenance of the generator, including the control board, can help avoid such issues.

3 . Screen Backlight Failure

One of the less common but equally frustrating reasons for a blank LCD screen on your Generac generator may be a screen backlight failure

The backlight provides illumination, making the LCD screen readable in various lighting conditions. 

Components such as inverter circuits or cold cathode fluorescent lamps (CCFLs) failing, or simply the aging of parts, can lead to the backlight not functioning, rendering the screen unreadable or seemingly blank.

Key points to remember: Backlight provides illumination for the LCD screen. Its failure can be due to aging, faulty inverter circuits, or failing CCFLs.

Solution

Addressing a screen backlight failure generally requires professional servicing. In some cases, replacing the defective components can solve the problem. In others, the entire LCD module might need replacement. 

While this is being fixed, ensure proper maintenance practices are adhered to in order to prolong the life of the new parts and prevent future failures.

Key points to remember: Professional servicing is needed for backlight failure.

 The solution can involve replacing defective components or the entire LCD module. Regular maintenance can prevent future issues.

4 . Incompatible Software Updates

One of the more technical reasons for a Generac generator’s LCD screen turning blank may be an incompatible software update

The generator’s management system operates on sophisticated software that requires updates to function optimally.

 However, if an update is incompatible due to reasons like incorrect format or version, it can interfere with the system’s normal operation and cause the LCD screen to go blank.

Key points to remember: The LCD screen may go blank due to incompatible software updates, particularly when the update is of the incorrect format or version.

Solution

If the LCD screen has gone blank following a software update, it would be advisable to revert back to the previous software version if possible

 If this doesn’t solve the problem or isn’t an option, professional assistance should be sought. 

A certified Generac technician can diagnose the issue, install the correct software version, and ensure the generator’s system is functioning as expected.

Key points to remember: Reverting to the previous software version may solve the issue. If not, professional assistance is needed to install the correct software version.

5 . Damaged LCD Connection

One of the potential causes for a blank LCD screen on your Generac generator could be a damaged LCD connection

The LCD screen is connected to the generator’s system through various cables and connectors. 

Over time, these connections can deteriorate due to wear and tear, external damage, or faulty installation. 

When this happens, the communication between the LCD screen and the generator’s system is interrupted, leading to a blank screen.

Key points to remember: Damaged LCD connection can interrupt communication between the LCD screen and the generator’s system, leading to a blank screen

This can be due to wear and tear, external damage, or faulty installation.

Solution

Addressing a damaged LCD connection requires careful inspection and typically, professional help. 

A certified technician can examine the cables and connectors, identify the exact problem, and carry out necessary repairs or replacements. 

If you have the necessary skills, you might be able to tighten loose connections or replace damaged cables yourself, but caution should be exercised to avoid further damage or safety risks.

Key points to remember: A certified technician can examine the cables and connectors and carry out necessary repairs or replacements.

 With the necessary skills, it might be possible to tighten loose connections or replace damaged cables.

6 . Internal Component Failure

One of the possible causes for a blank LCD screen on your Generac generator can be an internal component failure.

 The generator is composed of several intricate parts working in unison. 

Over time, these components can malfunction due to a myriad of reasons such as age, usage frequency, and lack of maintenance. 

When these internal components fail, they can disrupt the normal functioning of the LCD screen, leading to a blank display.

Key points to remember: Internal components can fail due to age, usage frequency, or lack of maintenance. This failure can disrupt the normal functioning of the LCD screen, causing it to go blank.

Solution

When internal component failure is the issue, the solution often involves identifying and replacing the faulty parts.

 Professional assistance is highly advisable in such instances, as it requires technical know-how to diagnose and address the issue effectively. 

Regular maintenance checks, carried out by a certified Generac technician, can help identify potential problems early and prevent component failure, thereby avoiding a blank LCD screen.

Key points to remember: Replacing faulty parts often solves the issue of internal component failure. 

Conclusion

In conclusion, a blank LCD screen on your Generac generator can be a source of frustration. 

However, various solutions exist to rectify this issue, ranging from battery and control board checks to professional servicing. Keeping your generator regularly maintained can avert such issues. 

It’s critical to remember that while minor troubleshooting can be done independently, professional assistance is necessary for more complex problems to avoid damaging the system further.

FAQs

What should I do if the LCD screen of my Generac generator goes blank?

Check the battery and control board; if the issue persists, seek professional assistance.

Can I fix a blank LCD screen on my Generac generator myself?

Minor troubleshooting can be done independently, but complex problems require professional help.

How can I prevent the LCD screen on my Generac generator from going blank?

Regular maintenance of your generator can help prevent such issues.

Is a blank LCD screen on a Generac generator a sign of a serious problem?

Not necessarily, it could be a minor issue like a battery failure or a sign of a more complex problem.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top